Air Pressure |
20 inches of water (maximum) |
Outflow Air Temp |
130—140 F |
Engine RPM |
Idle to 2,800 rpm max |
Engine Coolant Temp |
Maintain below 210 F |
Fuel Capacity |
50 US gallons |
BTU Per Hour |
900,000 |
The heater has a cold start function that will heat the unit as fast as possible, and once at operating temperature, will produce constant output duct air of 130 F. The unit automatically adjusts to all plane sizes, maintaining Air Pressure to a maximum of 20 inches of water.
The System monitors vital engine temperatures such as coolant and oil, ensuring the unit’s engine does not overheat. By automatically controlling the “Variflow” air damper and the engine’s RPMs CALISTA produces the ideal output air temperature at the ideal air pressure.
The days of constantly monitoring your heater and making ongoing adjustments because of varying daily temperatures and sizes of airplanes are now over.